using System.Reflection; using System.Runtime.Loader; using Mono.Cecil; using Mono.Cecil.Cil; using XfeBootPlatformPatch; internal static class LatencyClockChecks { public static void Run(AssemblyDefinition originalCoreX64, AssemblyDefinition patchedCoreX64, AssemblyDefinition originalHal, AssemblyDefinition patchedHal, AssemblyDefinition commonCore, Action check) { var apic = originalCoreX64.MainModule.Types.Single(type => type.Name == "LocalApic"); var originalStart = apic.Methods.Single(method => method.Name == "StartPeriodicTimer"); var patchedStart = patchedCoreX64.MainModule.Types.Single(type => type.Name == "LocalApic").Methods.Single(method => method.Name == "StartPeriodicTimer"); check("LatencyLapicCounterCalibrationAndIntervalWriterUnchanged", PlatformPatch.Fingerprint(originalStart) == PlatformPatch.Fingerprint(patchedStart)); var callback = PlatformPatch.Timer(patchedCoreX64); var callbackCall = callback.Body.Instructions.Single(instruction => instruction.Operand is MethodReference method && method.Name == "OnTimerInterrupt"); check("LatencyIsrElapsedArgumentUsesProgrammedIntervalNs", callbackCall.Previous.OpCode == OpCodes.Ldsfld && callbackCall.Previous.Operand is FieldReference field && field.Name == "s_timerIntervalNs"); var manager = commonCore.MainModule.Types.Single(type => type.Name == "SchedulerManager"); var tick = manager.Methods.Single(method => method.Name == "OnTimerInterrupt"); check("LatencySchedulerReportsActualElapsedArgument", tick.Body.Instructions.Single(instruction => instruction.Operand is FieldReference field && field.Name == "s_tickPeriodNs" && instruction.OpCode == OpCodes.Stsfld).Previous.OpCode == OpCodes.Ldarg_2); var clock = manager.Methods.Single(method => method.Name == "GetTimestamp"); check("LatencySleepClockReadsStopwatchNotTickCount", clock.Body.Instructions.Any(instruction => instruction.Operand is MethodReference method && method.FullName == "System.Int64 System.Diagnostics.Stopwatch::GetTimestamp()") && !clock.Body.Instructions.Any(instruction => instruction.OpCode == OpCodes.Ldsfld)); var sleeping = manager.Methods.Single(method => method.Name == "MarkSleeping"); check("LatencySleepDeadlineUsesStopwatchFrequencyPerMillisecond", sleeping.Body.Instructions.Any(instruction => instruction.OpCode == OpCodes.Ldsfld && instruction.Operand is FieldReference field && field.FullName == "System.Int64 System.Diagnostics.Stopwatch::Frequency") && sleeping.Body.Instructions.Any(instruction => instruction.OpCode == OpCodes.Ldc_I4 && Equals(instruction.Operand, 1000)) && sleeping.Body.Instructions.Any(instruction => instruction.Operand is MethodReference method && method.Name == "set_WakeupTime") && sleeping.Body.Instructions.All(instruction => instruction.Operand is not FieldReference field || field.Name != "s_tickCount")); using var oldRunner = new Runner(originalStart, LatencyPolicyPatch.SchedulerTimer(originalHal)); using var newRunner = new Runner(patchedStart, LatencyPolicyPatch.SchedulerTimer(patchedHal)); var old = oldRunner.Run(10); var current = newRunner.Run(10); var arbitrary = newRunner.Run(43); check("LatencyActualLapicArithmeticTenMillisecondControl", old == new LatencyClockFixture.Observation(10, 10_000_000, 1_000_000, 1, 3)); check("LatencyActualLapicArithmeticAndHardwareCountBothOneMillisecond", current == new LatencyClockFixture.Observation(1, 1_000_000, 100_000, 1, 3)); check("LatencyHalAlwaysProgramsOneMillisecondNotCallerAccountingQuantum", arbitrary == current); check("LatencyTenOneMsIrqsEqualOneOldTickElapsed", current.ElapsedNanoseconds * 10 == old.ElapsedNanoseconds && current.InitialHardwareCount * 10 == old.InitialHardwareCount); } private sealed class Runner : IDisposable { private readonly AssemblyLoadContext context = new("LapicClockArithmetic", true); private readonly MethodInfo setup; public Runner(MethodDefinition originalStart, MethodDefinition originalSetup) { using var assembly = AssemblyDefinition.CreateAssembly(new("ClockFixture_" + Guid.NewGuid().ToString("N"), new Version(1, 0)), "ClockFixture", ModuleKind.Dll); var module = assembly.MainModule; var type = new TypeDefinition("Fixture", "Callbacks", Mono.Cecil.TypeAttributes.Public | Mono.Cecil.TypeAttributes.Abstract | Mono.Cecil.TypeAttributes.Sealed, module.TypeSystem.Object); module.Types.Add(type); var start = new MethodDefinition("StartPeriodicTimer", Mono.Cecil.MethodAttributes.Public | Mono.Cecil.MethodAttributes.Static, module.TypeSystem.Void); start.Parameters.Add(new(module.TypeSystem.UInt32)); type.Methods.Add(start); start.Body.InitLocals = true; start.Body.Variables.Add(new(module.TypeSystem.UInt32)); start.Body.MaxStackSize = 3; var instructions = originalStart.Body.Instructions; int begin = instructions.IndexOf(instructions.First(instruction => instruction.OpCode == OpCodes.Ldsfld && instruction.Operand is FieldReference field && field.Name == "s_ticksPerMs")); int end = instructions.IndexOf(instructions.Single(instruction => instruction.OpCode == OpCodes.Stsfld && instruction.Operand is FieldReference field && field.Name == "s_timerIntervalNs")); int writes = instructions.IndexOf(instructions.Single(instruction => instruction.OpCode == OpCodes.Ldc_I4 && Equals(instruction.Operand, 992))); // Execute the exact source arithmetic and MMIO-write arguments. Only // static state and hardware Write tokens are replaced by host doubles; // startup string formatting is outside this timing arithmetic control. foreach (var source in instructions.Skip(begin).Take(end - begin + 1).Concat(instructions.Skip(writes))) { var clone = Instruction.Create(OpCodes.Nop); clone.OpCode = source.OpCode; clone.Operand = source.Operand switch { FieldReference field => module.ImportReference(typeof(LatencyClockFixture).GetField(field.Name)!), MethodReference method when method.Name == "Write" => module.ImportReference(typeof(LatencyClockFixture).GetMethod("Write")!), VariableDefinition variable => start.Body.Variables[variable.Index], null => null, _ => source.Operand }; start.Body.Instructions.Add(clone); } var setup = new MethodDefinition("Setup", Mono.Cecil.MethodAttributes.Public | Mono.Cecil.MethodAttributes.Static, module.TypeSystem.Void); setup.Parameters.Add(new(module.TypeSystem.Object)); setup.Parameters.Add(new(module.TypeSystem.UInt32)); type.Methods.Add(setup); foreach (var source in originalSetup.Body.Instructions) { var clone = Instruction.Create(OpCodes.Nop); clone.OpCode = source.OpCode; clone.Operand = source.Operand is MethodReference call ? call.Name switch { "StartPeriodicTimer" => start, "RegisterTimerHandler" => module.ImportReference(typeof(LatencyClockFixture).GetMethod("RegisterTimerHandler")!), "WriteString" => module.ImportReference(typeof(LatencyClockFixture).GetMethod("WriteString")!), _ => throw new InvalidOperationException("Unknown LAPIC setup callback") } : source.Operand; setup.Body.Instructions.Add(clone); } using var stream = new MemoryStream(); assembly.Write(stream); stream.Position = 0; this.setup = context.LoadFromStream(stream).GetType("Fixture.Callbacks", true)!.GetMethod("Setup")!; } public LatencyClockFixture.Observation Run(uint requested) { LatencyClockFixture.Reset(); setup.Invoke(null, [null, requested]); return LatencyClockFixture.Read(); } public void Dispose() => context.Unload(); } } public static class LatencyClockFixture { public static uint s_ticksPerMs, s_timerIntervalMs; public static ulong s_timerIntervalNs; private static uint initialCount; private static int registered, writes; public static void Reset() { s_ticksPerMs = 100_000; s_timerIntervalMs = 0; s_timerIntervalNs = 0; initialCount = 0; registered = writes = 0; } public static void Write(uint address, uint value) { writes++; if (address == 896) initialCount = value; } public static void WriteString(string value) { } public static void RegisterTimerHandler() => registered++; public static Observation Read() => new(s_timerIntervalMs, s_timerIntervalNs, initialCount, registered, writes); public sealed record Observation(uint IntervalMilliseconds, ulong ElapsedNanoseconds, uint InitialHardwareCount, int Registered, int Writes); }